MEASUREMENT
The building is measured in accordance with the BOMA/ANSI
Z65.1-1996 method of measurement.
Tower 1 (333,882)
Tower 2 (319,523)
Retail (62,472)
Health Club (49,506)
50 State Street (79,430)
Total 844,813
ELECTRICITY
Landlord provides up to four watts per usable square foot in the
premises, which is sufficient for standard lighting and office
machines.
PARKING
State House Square has a 445 car parking garage.Tenants are
provided with one parking space in the State House Square
garage per 2,000 square feet leased. The landlord has made
arrangements for additional parking for its tenants.
BUILDING SPECIFICATIONS
Normal hours of HVAC service:
Monday-Friday 8 a.m.-6 p.m.
Saturday 8 a.m.-1 p.m.
Space conditioning is provided through a variable air volume (VAV)
Space conditioning is provided through
a variable air volume (VAV) distribution
system with approximately 25-30 VAV
units per floor (approximately 1,000 SF
per zone).The ceiling mounted VAV units
are supplied conditioned air from four
central air handling units that maintain a
static pressure set point of 1.5 inches of
water (wg). Return air is drawn through
light troffers by four central return fans
to an open ceiling plenum back to the
mechanical penthouse.Thermostats in
various zones control the VAV units and
modulate space temperature.
Design Parameters
-
70°F
(+/- 2.5°F) during heating season
with outdoor temperature range of
0°F to 65°F.
-
76°F (+/- 2°F) (50% relative humidity)
during cooling season with outdoor
temperatures 91°F dry bulb and
77°F wet bulb.
-
Maximum o 78°F during intermediate
seasons with outdoor temperatures
from 55°F to 70°F
-
Outdoor air percentage 20%
CHILLED/CONDENSER WATER
The Energy Network provides, treats,
and maintains chilled water for State
House Square. Chilled water for normal
cooling is provided within the base rent.
Additional chilled water for supplemental
cooling will be billed to tenant at landlord’s
actual cost.There is no tap-in
charge for tenant to connect to the riser.
BUILDING ACCESS
On-site security is present 24 hours a
day, 7 days per week. Each tower is currently
manned by security Monday-Friday
6 a.m.-9 p.m. and Saturdays 7 a.m.-6 p.m. In
addition, there is additional security in the
Food Court during peak usage (11 a.m.-2
p.m.). After hours access for pedestrians
is provided via a proximity card reader
at each tower and for vehicles at the
entrance to the garage.
FREIGHT ELEVATOR
A freight elevator with a capacity of
4,000 lbs. serves each tower.
SATELLITE DISH
The building has four communications
providers: SBC, AT&T, MCI and
ChoiceOne. Satellite dish space available.
FLOOR LOADS
Except for the second floor, the floor
system is designed to accommodate up
to eighty (80) pounds of live load and up
to twenty (20) pounds of partition, ceiling
and suspended mechanical equipment.
The second floor is designed to handle
one hundred (100) pounds of live load.
EMERGENCY POWER
Back-up generator space available
in parking area.
OTHER
On-site management office, storage
space available